Using regenerable filter cartridges with filter media of filter class H13, the residual dust values of the former HEPA filtration can be achieved with only one filter stage. Expensive process interruptions during filter replacement of the second filter stage are thus a thing of the past. In particularly sensitive areas, such as the chemicals or pharmaceutical industries, the filter module can be used as plug-in or top filter. Depending on the application, it serves as the first or second filter stage.
The filter module can be used for aspiration, for venting pneumatic conveyors, as a safety filter and for many other applications. The inflow of the filter surface takes place on the raw gas side from outside to inside. The contaminated star filter is pushed into a closed container as in a pneumatic tube system. Thus, the star filter can be disposed of free of contamination. The filter module can be used for the controlled course of an explosion in a pressure-resistant housing. It is flame-propagation-proof and holds back the whirling burning dust.
- 12 bar pressure resistant
- Star filter with filter media (Glass fibre-free): Filter class H13
Degrees of separation ≥ 99.995 %
Clean gas values <1 mg/m³ - Optionally filter element of metal
- Regenerable
- Suitable for potentially explosive atmospheres
- Food approval
- expandable by activated carbon (for example for the filtration of aromatics)
- Small and compact for low heights